| /*? Text: "%s: %d output lines suppressed due to ratelimiting\n" */ |
| /*? Text: "cpum_cf_diag counter set compare error in set %i\n" */ |
| /*? Text: "Registration of s390dbf(cpum_cf_diag) failed\n" */ |
| /*? Text: "Registration of PMU(cpum_cf_diag) failed with rc=%i\n" */ |
| |
| /*? |
| * Text: "Enabling the performance measuring unit failed with rc=%x\n" |
| * Severity: Error |
| * Parameter: |
| * @1: Error code returned by PMU enable function |
| * Description: |
| * The CPU Measurement Facilitiy for counters needs to be enabled to extract |
| * counter data. |
| * User action: |
| * To use the CPU-measurement counter facility, authorize the LPAR for each |
| * counter set you want to use. Customize the LPAR activation profile and modify |
| * the Counter Facility Security Options. Then reboot. |
| * If the problem persists, gather Linux debug data and report the |
| * problem to your support organization. |
| */ |
| |
| /*? |
| * Text: "Disabling the performance measuring unit failed with rc=%x\n" |
| * Severity: Error |
| * Parameter: |
| * @1: Error code returned by PMU disable function |
| * Description: |
| * The CPU Measurement Facilitiy for counters is disabled to stop extraction |
| * of counter data. |
| * User action: |
| * Reboot. If the problem persists, gather Linux debug data and report the |
| * problem to your support organization. |
| */ |
| |
| /*? |
| * Text: "Insufficient memory for PMU(cpum_cf_diag) need=%zu\n" |
| * Severity: Error |
| * Parameter: |
| * @1: Required amount of bytes needed to store the counter sets. |
| * Description: |
| * The preallocted memory to store counter sets is too small. |
| * User action: |
| * If the problem persists, gather Linux debug data and report the |
| * problem to your support organization. |
| */ |