| // SPDX-License-Identifier: GPL-2.0-or-later | |
| /* | |
| * db8500_thermal.c - DB8500 Thermal Management Implementation | |
| * | |
| * Copyright (C) 2012 ST-Ericsson | |
| * Copyright (C) 2012-2019 Linaro Ltd. | |
| * | |
| * Authors: Hongbo Zhang, Linus Walleij | |
| */ | |
| #include <linux/cpu_cooling.h> | |
| #include <linux/interrupt.h> | |
| #include <linux/mfd/dbx500-prcmu.h> | |
| #include <linux/module.h> | |
| #include <linux/of.h> | |
| #include <linux/platform_device.h> | |
| #include <linux/slab.h> | |
| #include <linux/thermal.h> | |
| #define PRCMU_DEFAULT_MEASURE_TIME 0xFFF | |
| #define PRCMU_DEFAULT_LOW_TEMP 0 | |
| /** | |
| * db8500_thermal_points - the interpolation points that trigger | |
| * interrupts | |
| */ | |
| static const unsigned long db8500_thermal_points[] = { | |
| 15000, | |
| 20000, | |
| 25000, | |
| 30000, | |
| 35000, | |
| 40000, | |
| 45000, | |
| 50000, | |
| 55000, | |
| 60000, | |
| 65000, | |
| 70000, | |
| 75000, | |
| 80000, | |
| /* | |
| * This is where things start to get really bad for the | |
| * SoC and the thermal zones should be set up to trigger | |
| * critical temperature at 85000 mC so we don't get above | |
| * this point. | |
| */ | |
| 85000, | |
| 90000, | |
| 95000, | |
| 100000, | |
| }; | |
| struct db8500_thermal_zone { | |
| struct thermal_zone_device *tz; | |
| enum thermal_trend trend; | |
| unsigned long interpolated_temp; | |
| unsigned int cur_index; | |
| }; | |
| /* Callback to get current temperature */ | |
| static int db8500_thermal_get_temp(void *data, int *temp) | |
| { | |
| struct db8500_thermal_zone *th = data; | |
| /* | |
| * TODO: There is no PRCMU interface to get temperature data currently, | |
| * so a pseudo temperature is returned , it works for thermal framework | |
| * and this will be fixed when the PRCMU interface is available. | |
| */ | |
| *temp = th->interpolated_temp; | |
| return 0; | |
| } | |
| /* Callback to get temperature changing trend */ | |
| static int db8500_thermal_get_trend(void *data, int trip, enum thermal_trend *trend) | |
| { | |
| struct db8500_thermal_zone *th = data; | |
| *trend = th->trend; | |
| return 0; | |
| } | |
| static struct thermal_zone_of_device_ops thdev_ops = { | |
| .get_temp = db8500_thermal_get_temp, | |
| .get_trend = db8500_thermal_get_trend, | |
| }; | |
| static void db8500_thermal_update_config(struct db8500_thermal_zone *th, | |
| unsigned int idx, | |
| enum thermal_trend trend, | |
| unsigned long next_low, | |
| unsigned long next_high) | |
| { | |
| prcmu_stop_temp_sense(); | |
| th->cur_index = idx; | |
| th->interpolated_temp = (next_low + next_high)/2; | |
| th->trend = trend; | |
| /* | |
| * The PRCMU accept absolute temperatures in celsius so divide | |
| * down the millicelsius with 1000 | |
| */ | |
| prcmu_config_hotmon((u8)(next_low/1000), (u8)(next_high/1000)); | |
| prcmu_start_temp_sense(PRCMU_DEFAULT_MEASURE_TIME); | |
| } | |
| static irqreturn_t prcmu_low_irq_handler(int irq, void *irq_data) | |
| { | |
| struct db8500_thermal_zone *th = irq_data; | |
| unsigned int idx = th->cur_index; | |
| unsigned long next_low, next_high; | |
| if (idx == 0) | |
| /* Meaningless for thermal management, ignoring it */ | |
| return IRQ_HANDLED; | |
| if (idx == 1) { | |
| next_high = db8500_thermal_points[0]; | |
| next_low = PRCMU_DEFAULT_LOW_TEMP; | |
| } else { | |
| next_high = db8500_thermal_points[idx - 1]; | |
| next_low = db8500_thermal_points[idx - 2]; | |
| } | |
| idx -= 1; | |
| db8500_thermal_update_config(th, idx, THERMAL_TREND_DROPPING, | |
| next_low, next_high); | |
| dev_dbg(&th->tz->device, | |
| "PRCMU set max %ld, min %ld\n", next_high, next_low); | |
| thermal_zone_device_update(th->tz, THERMAL_EVENT_UNSPECIFIED); | |
| return IRQ_HANDLED; | |
| } | |
| static irqreturn_t prcmu_high_irq_handler(int irq, void *irq_data) | |
| { | |
| struct db8500_thermal_zone *th = irq_data; | |
| unsigned int idx = th->cur_index; | |
| unsigned long next_low, next_high; | |
| int num_points = ARRAY_SIZE(db8500_thermal_points); | |
| if (idx < num_points - 1) { | |
| next_high = db8500_thermal_points[idx+1]; | |
| next_low = db8500_thermal_points[idx]; | |
| idx += 1; | |
| db8500_thermal_update_config(th, idx, THERMAL_TREND_RAISING, | |
| next_low, next_high); | |
| dev_info(&th->tz->device, | |
| "PRCMU set max %ld, min %ld\n", next_high, next_low); | |
| } else if (idx == num_points - 1) | |
| /* So we roof out 1 degree over the max point */ | |
| th->interpolated_temp = db8500_thermal_points[idx] + 1; | |
| thermal_zone_device_update(th->tz, THERMAL_EVENT_UNSPECIFIED); | |
| return IRQ_HANDLED; | |
| } | |
| static int db8500_thermal_probe(struct platform_device *pdev) | |
| { | |
| struct db8500_thermal_zone *th = NULL; | |
| struct device *dev = &pdev->dev; | |
| int low_irq, high_irq, ret = 0; | |
| th = devm_kzalloc(dev, sizeof(*th), GFP_KERNEL); | |
| if (!th) | |
| return -ENOMEM; | |
| low_irq = platform_get_irq_byname(pdev, "IRQ_HOTMON_LOW"); | |
| if (low_irq < 0) { | |
| dev_err(dev, "Get IRQ_HOTMON_LOW failed\n"); | |
| return low_irq; | |
| } | |
| ret = devm_request_threaded_irq(dev, low_irq, NULL, | |
| prcmu_low_irq_handler, IRQF_NO_SUSPEND | IRQF_ONESHOT, | |
| "dbx500_temp_low", th); | |
| if (ret < 0) { | |
| dev_err(dev, "failed to allocate temp low irq\n"); | |
| return ret; | |
| } | |
| high_irq = platform_get_irq_byname(pdev, "IRQ_HOTMON_HIGH"); | |
| if (high_irq < 0) { | |
| dev_err(dev, "Get IRQ_HOTMON_HIGH failed\n"); | |
| return high_irq; | |
| } | |
| ret = devm_request_threaded_irq(dev, high_irq, NULL, | |
| prcmu_high_irq_handler, IRQF_NO_SUSPEND | IRQF_ONESHOT, | |
| "dbx500_temp_high", th); | |
| if (ret < 0) { | |
| dev_err(dev, "failed to allocate temp high irq\n"); | |
| return ret; | |
| } | |
| /* register of thermal sensor and get info from DT */ | |
| th->tz = devm_thermal_zone_of_sensor_register(dev, 0, th, &thdev_ops); | |
| if (IS_ERR(th->tz)) { | |
| dev_err(dev, "register thermal zone sensor failed\n"); | |
| return PTR_ERR(th->tz); | |
| } | |
| dev_info(dev, "thermal zone sensor registered\n"); | |
| /* Start measuring at the lowest point */ | |
| db8500_thermal_update_config(th, 0, THERMAL_TREND_STABLE, | |
| PRCMU_DEFAULT_LOW_TEMP, | |
| db8500_thermal_points[0]); | |
| platform_set_drvdata(pdev, th); | |
| return 0; | |
| } | |
| static int db8500_thermal_suspend(struct platform_device *pdev, | |
| pm_message_t state) | |
| { | |
| prcmu_stop_temp_sense(); | |
| return 0; | |
| } | |
| static int db8500_thermal_resume(struct platform_device *pdev) | |
| { | |
| struct db8500_thermal_zone *th = platform_get_drvdata(pdev); | |
| /* Resume and start measuring at the lowest point */ | |
| db8500_thermal_update_config(th, 0, THERMAL_TREND_STABLE, | |
| PRCMU_DEFAULT_LOW_TEMP, | |
| db8500_thermal_points[0]); | |
| return 0; | |
| } | |
| static const struct of_device_id db8500_thermal_match[] = { | |
| { .compatible = "stericsson,db8500-thermal" }, | |
| {}, | |
| }; | |
| MODULE_DEVICE_TABLE(of, db8500_thermal_match); | |
| static struct platform_driver db8500_thermal_driver = { | |
| .driver = { | |
| .name = "db8500-thermal", | |
| .of_match_table = of_match_ptr(db8500_thermal_match), | |
| }, | |
| .probe = db8500_thermal_probe, | |
| .suspend = db8500_thermal_suspend, | |
| .resume = db8500_thermal_resume, | |
| }; | |
| module_platform_driver(db8500_thermal_driver); | |
| MODULE_AUTHOR("Hongbo Zhang <hongbo.zhang@stericsson.com>"); | |
| MODULE_DESCRIPTION("DB8500 thermal driver"); | |
| MODULE_LICENSE("GPL"); |