blob: a02039e3aca0e31d786c91dbec6c6b5dd620b97a [file] [log] [blame]
# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
%YAML 1.2
---
$id: http://devicetree.org/schemas/display/dsi-controller.yaml#
$schema: http://devicetree.org/meta-schemas/core.yaml#
title: Common Properties for DSI Display Panels
maintainers:
- Linus Walleij <linus.walleij@linaro.org>
description: |
This document defines device tree properties common to DSI, Display
Serial Interface controllers and attached panels. It doesn't constitute
a device tree binding specification by itself but is meant to be referenced
by device tree bindings.
When referenced from panel device tree bindings the properties defined in
this document are defined as follows. The panel device tree bindings are
responsible for defining whether each property is required or optional.
Notice: this binding concerns DSI panels connected directly to a master
without any intermediate port graph to the panel. Each DSI master
can control one to four virtual channels to one panel. Each virtual
channel should have a node "panel" for their virtual channel with their
reg-property set to the virtual channel number, usually there is just
one virtual channel, number 0.
properties:
$nodename:
pattern: "^dsi(@.*)?$"
"#address-cells":
const: 1
"#size-cells":
const: 0
patternProperties:
"^panel@[0-3]$":
description: Panels connected to the DSI link
type: object
properties:
reg:
minimum: 0
maximum: 3
description:
The virtual channel number of a DSI peripheral. Must be in the range
from 0 to 3, as DSI uses a 2-bit addressing scheme. Some DSI
peripherals respond to more than a single virtual channel. In that
case the reg property can take multiple entries, one for each virtual
channel that the peripheral responds to.
clock-master:
type: boolean
description:
Should be enabled if the host is being used in conjunction with
another DSI host to drive the same peripheral. Hardware supporting
such a configuration generally requires the data on both the busses
to be driven by the same clock. Only the DSI host instance
controlling this clock should contain this property.
enforce-video-mode:
type: boolean
description:
The best option is usually to run a panel in command mode, as this
gives better control over the panel hardware. However for different
reasons like broken hardware, missing features or testing, it may be
useful to be able to force a command mode-capable panel into video
mode.
required:
- reg
examples:
- |
#include <dt-bindings/gpio/gpio.h>
dsi@a0351000 {
reg = <0xa0351000 0x1000>;
#address-cells = <1>;
#size-cells = <0>;
panel@0 {
compatible = "sony,acx424akp";
reg = <0>;
vddi-supply = <&ab8500_ldo_aux1_reg>;
reset-gpios = <&gpio2 1 GPIO_ACTIVE_LOW>;
};
};
...