tools/power turbostat: Avoid probing the same perf counters
For the RAPL package energy status counter, Intel and AMD share the same
perf_subsys and perf_name, but with different MSR addresses.
Both rapl_counter_arch_infos[0] and rapl_counter_arch_infos[1] are
introduced to describe this counter for different Vendors.
As a result, the perf counter is probed twice, and causes a failure in
in get_rapl_counters() because expected_read_size and actual_read_size
don't match.
Fix the problem by skipping the already probed counter.
Note, this is not a perfect fix. For example, if different
vendors/platforms use the same MSR value for different purpose, the code
can be fooled when it probes a rapl_counter_arch_infos[] entry that does
not belong to the running Vendor/Platform.
In a long run, better to put rapl_counter_arch_infos[] into the
platform_features so that this becomes Vendor/Platform specific.