wireless-regdb: update regulatory rules for Bosnia and Herzegovina (BA) for 6 GHz
For CEPT countries, ECC/DEC/(20)01 [1][2] decision enters into force
on 8 November 2024; preferred date for implementation of this Decision
shall be 8 May 2025. Update regulatory rule for Bosnia and Herzegovina
accordingly.
* LPI devices
- 5945-6425 MHz
- Restricted to indoor use only
- Maximum mean e.i.r.p.: 23 dBm
- Maximum mean e.i.r.p. density: 10 dBm/MHz
* VLP devices
- 5945-6425 MHz
- Indoors and outdoors
- Maximum mean e.i.r.p.: 14 dBm
- Maximum mean e.i.r.p. density: 1 dBm/MHz
[1] https://docdb.cept.org/implementation/16737
[2] https://docdb.cept.org/download/4685
Signed-off-by: Ping-Ke Shih <pkshih@realtek.com>
Link: https://lore.kernel.org/r/20250708113544.3557-1-pkshih@gmail.com
Signed-off-by: Chen-Yu Tsai <wens@kernel.org>