|  | Kernel driver sht15 | 
|  | =================== | 
|  |  | 
|  | Authors: | 
|  | * Wouter Horre | 
|  | * Jonathan Cameron | 
|  | * Vivien Didelot <vivien.didelot@savoirfairelinux.com> | 
|  | * Jerome Oufella <jerome.oufella@savoirfairelinux.com> | 
|  |  | 
|  | Supported chips: | 
|  | * Sensirion SHT10 | 
|  | Prefix: 'sht10' | 
|  |  | 
|  | * Sensirion SHT11 | 
|  | Prefix: 'sht11' | 
|  |  | 
|  | * Sensirion SHT15 | 
|  | Prefix: 'sht15' | 
|  |  | 
|  | * Sensirion SHT71 | 
|  | Prefix: 'sht71' | 
|  |  | 
|  | * Sensirion SHT75 | 
|  | Prefix: 'sht75' | 
|  |  | 
|  | Datasheet: Publicly available at the Sensirion website | 
|  | http://www.sensirion.ch/en/pdf/product_information/Datasheet-humidity-sensor-SHT1x.pdf | 
|  |  | 
|  | Description | 
|  | ----------- | 
|  |  | 
|  | The SHT10, SHT11, SHT15, SHT71, and SHT75 are humidity and temperature | 
|  | sensors. | 
|  |  | 
|  | The devices communicate using two GPIO lines. | 
|  |  | 
|  | Supported resolutions for the measurements are 14 bits for temperature and 12 | 
|  | bits for humidity, or 12 bits for temperature and 8 bits for humidity. | 
|  |  | 
|  | The humidity calibration coefficients are programmed into an OTP memory on the | 
|  | chip. These coefficients are used to internally calibrate the signals from the | 
|  | sensors. Disabling the reload of those coefficients allows saving 10ms for each | 
|  | measurement and decrease power consumption, while loosing on precision. | 
|  |  | 
|  | Some options may be set directly in the sht15_platform_data structure | 
|  | or via sysfs attributes. | 
|  |  | 
|  | Notes: | 
|  | * The regulator supply name is set to "vcc". | 
|  | * If a CRC validation fails, a soft reset command is sent, which resets | 
|  | status register to its hardware default value, but the driver will try to | 
|  | restore the previous device configuration. | 
|  |  | 
|  | Platform data | 
|  | ------------- | 
|  |  | 
|  | * checksum: | 
|  | set it to true to enable CRC validation of the readings (default to false). | 
|  | * no_otp_reload: | 
|  | flag to indicate not to reload from OTP (default to false). | 
|  | * low_resolution: | 
|  | flag to indicate the temp/humidity resolution to use (default to false). | 
|  |  | 
|  | Sysfs interface | 
|  | --------------- | 
|  |  | 
|  | * temp1_input:     temperature input | 
|  | * humidity1_input: humidity input | 
|  | * heater_enable:   write 1 in this attribute to enable the on-chip heater, | 
|  | 0 to disable it. Be careful not to enable the heater | 
|  | for too long. | 
|  | * temp1_fault:     if 1, this means that the voltage is low (below 2.47V) and | 
|  | measurement may be invalid. | 
|  | * humidity1_fault: same as temp1_fault. |