| # sysstat.py - rteval measurment module collecting system statistics |
| # using the sysstat utility |
| # |
| # Copyright 2013 David Sommerseth <davids@redhat.com> |
| # |
| # This program is free software; you can redistribute it and/or modify |
| # it under the terms of the GNU General Public License as published by |
| # the Free Software Foundation; either version 2 of the License, or |
| # (at your option) any later version. |
| # |
| # This program is distributed in the hope that it will be useful, |
| # but WITHOUT ANY WARRANTY; without even the implied warranty of |
| # MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the |
| # GNU General Public License for more details. |
| # |
| # You should have received a copy of the GNU General Public License along |
| # with this program; if not, write to the Free Software Foundation, Inc., |
| # 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301 USA. |
| # |
| # For the avoidance of doubt the "preferred form" of this code is one which |
| # is in an open unpatent encumbered format. Where cryptographic key signing |
| # forms part of the process of creating an executable the information |
| # including keys needed to generate an equivalently functional executable |
| # are deemed to be part of the source code. |
| # |
| |
| import os, sys, libxml2, tempfile, time, subprocess, base64, bz2, textwrap |
| from rteval.Log import Log |
| from rteval.modules import rtevalModulePrototype |
| |
| |
| class sysstat(rtevalModulePrototype): |
| def __init__(self, config, logger=None): |
| rtevalModulePrototype.__init__(self, 'measurement', 'sysstat', logger) |
| self.__cfg = config |
| self.__started = False |
| self.__logentry = 0 |
| self.__bin_sadc = "/usr/lib64/sa/sadc" # FIXME: Do dynamically |
| self.__datadir = os.path.join(self.__cfg.reportdir, 'sysstat') |
| self.__datafile = os.path.join(self.__datadir, "sysstat.dat") |
| |
| |
| def _WorkloadSetup(self): |
| # Nothing to do here for sysstat |
| pass |
| |
| |
| def _WorkloadBuild(self): |
| # Nothing to build |
| self._setReady() |
| |
| |
| def _WorkloadPrepare(self): |
| os.mkdir(self.__datadir) |
| |
| |
| def _WorkloadTask(self): |
| # This workload will actually not run any process, but |
| # it will update the data files each time rteval checks |
| # if this workload is alive. |
| # |
| # Just add a single notification that rteval started |
| if self.__logentry == 0: |
| cmd = [self.__bin_sadc, "-S", "XALL", "-C", "rteval started", self.__datafile] |
| subprocess.call(cmd) |
| self.__logentry += 1 |
| |
| |
| def WorkloadAlive(self): |
| # Here the sysstat tool will be called, which will update |
| # the file containing the system information |
| cmd = [self.__bin_sadc, "-S", "XALL", "1", "1", self.__datafile] |
| subprocess.call(cmd) |
| self.__logentry += 1 |
| return True |
| |
| |
| def _WorkloadCleanup(self): |
| # Add 'rteval stopped' comment line |
| cmd = [self.__bin_sadc, "-S", "XALL", "-C", "rteval stopped", self.__datafile] |
| subprocess.call(cmd) |
| self.__logentry += 1 |
| self._setFinished() |
| |
| |
| def MakeReport(self): |
| rep_n = libxml2.newNode('sysstat') |
| rep_n.newProp('command_line', '(sysstat specifics)') |
| rep_n.newProp('num_entries', str(self.__logentry)) |
| |
| fp = open(self.__datafile, "rb") |
| compr = bz2.BZ2Compressor(9) |
| cmpr = compr.compress(fp.read()) |
| data = base64.b64encode(cmpr + compr.flush()) |
| data_n = rep_n.newTextChild(None, 'data', "\n"+"\n".join(textwrap.wrap(data,75))+"\n") |
| data_n.newProp('contents', 'sysstat/sar binary data') |
| data_n.newProp('encoding','base64') |
| data_n.newProp('compression','bz2') |
| fp.close() |
| del cmpr |
| del compr |
| |
| # Return the report |
| return rep_n |
| |
| |
| |
| def ModuleInfo(): |
| # sysstat features - run in parallel with outher measurement modules with loads |
| return {"parallel": True, |
| "loads": True} |
| |
| |
| |
| def ModuleParameters(): |
| return {} # No arguments available |
| |
| |
| |
| def create(params, logger): |
| return sysstat(params, logger) |
| |
| |
| if __name__ == '__main__': |
| from rteval.rtevalConfig import rtevalConfig |
| |
| l = Log() |
| l.SetLogVerbosity(Log.INFO|Log.DEBUG|Log.ERR|Log.WARN) |
| |
| cfg = rtevalConfig({}, logger=l) |
| prms = {} |
| modprms = ModuleParameters() |
| for c, p in modprms.items(): |
| prms[c] = p['default'] |
| cfg.AppendConfig('MeasurementModuleTemplate', prms) |
| |
| cfg_ct = cfg.GetSection('MeasurementModuleTemplate') |
| cfg_ct.reportdir = "." |
| |
| runtime = 10 |
| |
| c = sysstat(cfg_ct, l) |
| c._WorkloadSetup() |
| c._WorkloadPrepare() |
| c._WorkloadTask() |
| print "Running for approx %i seconds" % runtime |
| while runtime > 0: |
| c.WorkloadAlive() |
| time.sleep(1) |
| runtime -= 1 |
| c._WorkloadCleanup() |
| rep_n = c.MakeReport() |
| |
| xml = libxml2.newDoc('1.0') |
| xml.setRootElement(rep_n) |
| xml.saveFormatFileEnc('-','UTF-8',1) |