| What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sys_calibration |
| KernelVersion: 5.5 |
| Contact: linux-iio@vger.kernel.org |
| Description: |
| This attribute, if available, initiates the system calibration procedure. This is done on a |
| single channel at a time. Write '1' to start the calibration. |
| |
| What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sys_calibration_mode_available |
| KernelVersion: 5.5 |
| Contact: linux-iio@vger.kernel.org |
| Description: |
| This attribute, if available, returns a list with the possible calibration modes. |
| There are two available options: |
| "zero_scale" - calibrate to zero scale |
| "full_scale" - calibrate to full scale |
| |
| What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sys_calibration_mode |
| KernelVersion: 5.5 |
| Contact: linux-iio@vger.kernel.org |
| Description: |
| This attribute, if available, sets up the calibration mode used in the system calibration |
| procedure. Reading returns the current calibration mode. |
| Writing sets the system calibration mode. |