| // SPDX-License-Identifier: GPL-2.0-or-later | 
 | /* Lantiq cpu temperature sensor driver | 
 |  * | 
 |  * Copyright (C) 2017 Florian Eckert <fe@dev.tdt.de> | 
 |  */ | 
 |  | 
 | #include <linux/bitops.h> | 
 | #include <linux/delay.h> | 
 | #include <linux/hwmon.h> | 
 | #include <linux/hwmon-sysfs.h> | 
 | #include <linux/init.h> | 
 | #include <linux/mod_devicetable.h> | 
 | #include <linux/module.h> | 
 | #include <linux/platform_device.h> | 
 |  | 
 | #include <lantiq_soc.h> | 
 |  | 
 | /* gphy1 configuration register contains cpu temperature */ | 
 | #define CGU_GPHY1_CR   0x0040 | 
 | #define CGU_TEMP_PD    BIT(19) | 
 |  | 
 | static void ltq_cputemp_enable(void) | 
 | { | 
 | 	ltq_cgu_w32(ltq_cgu_r32(CGU_GPHY1_CR) | CGU_TEMP_PD, CGU_GPHY1_CR); | 
 | } | 
 |  | 
 | static void ltq_cputemp_disable(void *data) | 
 | { | 
 | 	ltq_cgu_w32(ltq_cgu_r32(CGU_GPHY1_CR) & ~CGU_TEMP_PD, CGU_GPHY1_CR); | 
 | } | 
 |  | 
 | static int ltq_read(struct device *dev, enum hwmon_sensor_types type, | 
 | 		    u32 attr, int channel, long *temp) | 
 | { | 
 | 	int value; | 
 |  | 
 | 	switch (attr) { | 
 | 	case hwmon_temp_input: | 
 | 		/* get the temperature including one decimal place */ | 
 | 		value = (ltq_cgu_r32(CGU_GPHY1_CR) >> 9) & 0x01FF; | 
 | 		value = value * 5; | 
 | 		/* range -38 to +154 °C, register value zero is -38.0 °C */ | 
 | 		value -= 380; | 
 | 		/* scale temp to millidegree */ | 
 | 		value = value * 100; | 
 | 		break; | 
 | 	default: | 
 | 		return -EOPNOTSUPP; | 
 | 	} | 
 |  | 
 | 	*temp = value; | 
 | 	return 0; | 
 | } | 
 |  | 
 | static umode_t ltq_is_visible(const void *_data, enum hwmon_sensor_types type, | 
 | 			      u32 attr, int channel) | 
 | { | 
 | 	if (type != hwmon_temp) | 
 | 		return 0; | 
 |  | 
 | 	switch (attr) { | 
 | 	case hwmon_temp_input: | 
 | 		return 0444; | 
 | 	default: | 
 | 		return 0; | 
 | 	} | 
 | } | 
 |  | 
 | static const struct hwmon_channel_info * const ltq_info[] = { | 
 | 	HWMON_CHANNEL_INFO(chip, | 
 | 			   HWMON_C_REGISTER_TZ), | 
 | 	HWMON_CHANNEL_INFO(temp, | 
 | 			   HWMON_T_INPUT), | 
 | 	NULL | 
 | }; | 
 |  | 
 | static const struct hwmon_ops ltq_hwmon_ops = { | 
 | 	.is_visible = ltq_is_visible, | 
 | 	.read = ltq_read, | 
 | }; | 
 |  | 
 | static const struct hwmon_chip_info ltq_chip_info = { | 
 | 	.ops = <q_hwmon_ops, | 
 | 	.info = ltq_info, | 
 | }; | 
 |  | 
 | static int ltq_cputemp_probe(struct platform_device *pdev) | 
 | { | 
 | 	struct device *hwmon_dev; | 
 | 	int err = 0; | 
 |  | 
 | 	/* available on vr9 v1.2 SoCs only */ | 
 | 	if (ltq_soc_type() != SOC_TYPE_VR9_2) | 
 | 		return -ENODEV; | 
 |  | 
 | 	err = devm_add_action(&pdev->dev, ltq_cputemp_disable, NULL); | 
 | 	if (err) | 
 | 		return err; | 
 |  | 
 | 	ltq_cputemp_enable(); | 
 |  | 
 | 	hwmon_dev = devm_hwmon_device_register_with_info(&pdev->dev, | 
 | 							 "ltq_cputemp", | 
 | 							 NULL, | 
 | 							 <q_chip_info, | 
 | 							 NULL); | 
 |  | 
 | 	if (IS_ERR(hwmon_dev)) { | 
 | 		dev_err(&pdev->dev, "Failed to register as hwmon device"); | 
 | 		return PTR_ERR(hwmon_dev); | 
 | 	} | 
 |  | 
 | 	return 0; | 
 | } | 
 |  | 
 | const struct of_device_id ltq_cputemp_match[] = { | 
 | 	{ .compatible = "lantiq,cputemp" }, | 
 | 	{}, | 
 | }; | 
 | MODULE_DEVICE_TABLE(of, ltq_cputemp_match); | 
 |  | 
 | static struct platform_driver ltq_cputemp_driver = { | 
 | 	.probe = ltq_cputemp_probe, | 
 | 	.driver = { | 
 | 		.name = "ltq-cputemp", | 
 | 		.of_match_table = ltq_cputemp_match, | 
 | 	}, | 
 | }; | 
 |  | 
 | module_platform_driver(ltq_cputemp_driver); | 
 |  | 
 | MODULE_AUTHOR("Florian Eckert <fe@dev.tdt.de>"); | 
 | MODULE_DESCRIPTION("Lantiq cpu temperature sensor driver"); | 
 | MODULE_LICENSE("GPL"); |