blob: b30cf477ac3a9f4ef123c0e10716b4096a980f13 [file] [log] [blame]
From 804741ac7b9f2fdebe3740cb0579cb8d94d49e60 Mon Sep 17 00:00:00 2001
From: Mian Yousaf Kaukab <ykaukab@suse.de>
Date: Thu, 18 Mar 2021 09:50:26 +0100
Subject: netsec: restore phy power state after controller reset
From: Mian Yousaf Kaukab <ykaukab@suse.de>
commit 804741ac7b9f2fdebe3740cb0579cb8d94d49e60 upstream.
Since commit 8e850f25b581 ("net: socionext: Stop PHY before resetting
netsec") netsec_netdev_init() power downs phy before resetting the
controller. However, the state is not restored once the reset is
complete. As a result it is not possible to bring up network on a
platform with Broadcom BCM5482 phy.
Fix the issue by restoring phy power state after controller reset is
complete.
Fixes: 8e850f25b581 ("net: socionext: Stop PHY before resetting netsec")
Cc: stable@vger.kernel.org
Signed-off-by: Mian Yousaf Kaukab <ykaukab@suse.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
---
drivers/net/ethernet/socionext/netsec.c | 9 ++++++---
1 file changed, 6 insertions(+), 3 deletions(-)
--- a/drivers/net/ethernet/socionext/netsec.c
+++ b/drivers/net/ethernet/socionext/netsec.c
@@ -1693,14 +1693,17 @@ static int netsec_netdev_init(struct net
goto err1;
/* set phy power down */
- data = netsec_phy_read(priv->mii_bus, priv->phy_addr, MII_BMCR) |
- BMCR_PDOWN;
- netsec_phy_write(priv->mii_bus, priv->phy_addr, MII_BMCR, data);
+ data = netsec_phy_read(priv->mii_bus, priv->phy_addr, MII_BMCR);
+ netsec_phy_write(priv->mii_bus, priv->phy_addr, MII_BMCR,
+ data | BMCR_PDOWN);
ret = netsec_reset_hardware(priv, true);
if (ret)
goto err2;
+ /* Restore phy power state */
+ netsec_phy_write(priv->mii_bus, priv->phy_addr, MII_BMCR, data);
+
spin_lock_init(&priv->desc_ring[NETSEC_RING_TX].lock);
spin_lock_init(&priv->desc_ring[NETSEC_RING_RX].lock);